Dga test of transformer oil pdf merge

Performance of natural ester as a transformer oil in moisturerich environments. The risk of failure of transformers in service, based on dissolved gas analysis dga, depends on three main parameters. As the name implies, this test analyzes the type and quantity of gases that are dissolved in the transformer oil. With its individual and modular system components mte provides the optimal customer oriented solution for utilities, industries and transformer manufacturers. The distribution of these gases can be related to the type of electrical fault, and the rate of gas generation can indicate the severity of the fault. The dga test measures dissolved gases in the transformer oil and is capable of detecting. The technique explained above can be used to detect and determine fault gases at the desired trace ppm levels. Detects most internal faults, some external faults and some operational errors. Small samples of oil are taken for this test, using a clean, moisturefree containersyringe.

Type 2 this category covers any transformer showing test results where some concern is evident re test recommended in six months. Myrkos is supplied with the ppmreport control and database management software. For oils in service, an increasing or high color number is an indication of contamination, deterioration, or both. Insulating materials within transformers and electrical equipment break down to liberate gases within the unit. The oil sample is analysed in the laboratory using gas chromatography technique. Guest editorial understanding dissolved gas analysis dga. Evaluating transformer condition using dga oil analysis. Power transformer fault severity estimation based on dissolved. Product information dissolved gas analysis and supervision. The myrkos portable dga microgc is used with morgan schaffers shake test syringe to analyze oil samples within two minutes. The effect of transformer aging on dissolved combustible gasses is also examined. Transformer oil testing petroleum transformer free 30.

Regular sampling and testing of insulation oil taken from transformers is a valuable technique in a preventative maintenance pr ogram. From this method, the validation and test set errors have the same characteristics and. They can now be applied to transformers filled with beta fluid. As the concentration of dissolved gas in transformer oil has always been in a state of dynamic. New frontiers of dga interpretation for power transformers. Pdf evaluating the accuracy of different dga techniques for. Astm d3612a 15 gas chromatography for the energy industry july 17, 20. Prediction of dissolved gas concentrations in transformer oil.

Oil quality and dissolved gasses tests are comparatively used for this purpose. They are the vital links between generation and transmission. Many companies use the doble transformer oil purchase specification tops and the annual oil survey to qualify oil suppliers, using these materials as independent assessments of commercially available oils. Practical experience gained from dissolved gas analysis at an aluminium smelter ian. Thus, by merging thermal stress in paper and oil, the resulting. Pdf interpretation of dissolved gas analysis in transformer oil. Nov 15, 20 gc2010d measures dissolved gases in transformer oil. Performing tests to evaluate the quality of the transformer oil.

Dga, of a very healthy transformer and a transformer with severe fault are discussed. Gases generate by degradation of fluid or cellulose. Transformer monitoring mte meter test equipment ag. It is very important that a dga sample is kept airtight. More importantly, an oil sample can be taken at any time from most equipment without. Acidity test of transformer insulating oil electrical4u. Comprehensive multigas dga for your critical power transformers comprehensive multigas dga for your critical power transformers the vaisala optimus dga monitor gives you out of the box performance and offers the best longterm stable measurements with no maintenance. Both industrial transformer users and utilities are setting up these planned sampling programs using online devices that can monitor the oil for quality.

Exclusively for consultation by member of the ieee transformer committee 3152006 proposed gas level correlation between each level limit and the % of dga population below the limit. Classical dga systems falls under astmd3612 method a, and utilize a glass system with mercury for dissolved gas extraction from transformer oil 2. It can cause non availability of transformers for long hours. Then the extracted gases are separated, identified, and quantitatively determined. Dissolved gas analysis dga in transformer condition monitoring dissolved gas analysis is a method of monitoring the condition of electrical transformers and related oil filled equipment. Over time and due to electrical stresses and thermal decomposition, the cellulose paper and insulating mineral oil in paperoil insulation systems break down and forms gases which are dissolved in the oil. The dissolved gas analysis dga of transformers can provide an insight view related to thermal and electrical stresses during operations of oil immersed power transformers 1. Much like a blood test in humans, the results of an online dga of the transformer oil reveal developments inside the transformer.

Color d1500 the color of a new oil is generally accepted as an index of the degree of refinement. Importance of transformer processes the way a transformer is handled and the procedures that are used to receive, assemble, process and test the transformer are of fundamental importance to the long life of the transformer. Samples are generally sent to a laboratory for analysis but portable equipment is available to perform the. The dissolved gas analysis can give an early indication of abnormal conditions inside the transformer. Dissolved gas analysis dga is the study of dissolved gases in transformer oil insulating materials within transformers and electrical equipment break down to liberate gases within the unit. Dissolved gas analysis dga is a diagnostic tool that used to detect the incipient faults of power transformers through the correlation between the content of gases dissolved in transformers oil and a particular malfunction. Pdf evaluating transformer condition using dga oil analysis. Dissolved gas analysis dga is a test used to assess paperoil insulation systems, and the most commonly used technique for oilinsulated power transformers. Opt100 is the worlds first maintenance free multigas dga monitor. Dissolved gas analysis dga is the study of dissolved gases in transformer oil. Introduction transformer is one of the most important but complex component of electricity generation and transmission system. The standard test suites are designed for individual samples to deliver a routine set of oil analysis at low cost. It is the first indicator of a problem and can identify deteriorating insulation and oil, overheating, hot spots, partial discharge, and arcing.

The oil used in transformers as coolant and insulator has gases dissolved in it due to aging and faults inside the transformer. What is the normal frequency of transformer oil sampling. The published literature does not detail if arcing in a transformer can change stable sulfur species into reactive or corrosive forms. It is noted that the oil quality tests for transformer oil are inconclusive and that the dga test is then necessary. Dissolved gas analysis guide for transformers filled with. Assessing remnant life of transformer based on furan. It is noted that the oil quality tests for transformer oil are inconclusive and that the dga test is then necessary for complete evaluation of transformer condition. This test can give an early indication of abnormal behavior of the transformer. Dissolved gas concentration limit for interpretation of fault level as per ansiieee. Pdf influence of transformer oil aging byproducts on the. The operation is fully owned and operated by bhp billiton. Dga approaches the dga 18 is among the most common techniques used for online incipient fault diagnosis because the transformer need not be deenergized. Dga is accustomed to detect elementary faults in the transformer.

Transformer oil analysis testing service for monitoring the condition of transformer oils routine testing of transformer insulating oil is an essential maintenance function that ensures a safe working environment and helps eliminate the possibility of disrupted production resulting from a transformer failure or explosion. Reliabilitybased dga quick start guide for toa4 users. Power transformers, in order to assess the condition of windings, insulation, core, transformer oil. Reliabilitybased dga is a new method of dissolvedgas analysis interpretation, developed by deltax research. Identification of transformer fault based on dissolved gas. This glass system involves a vacuum pump with mercury vacuum gauge. Samples are generally sent to a laboratory for analysis but portable equipment is available to perform the test in the field. Practical experience gained from dissolved gas analysis at an. About 4 years back we have also started carrying out sfra sweep frequency response test. At present this entire technique is best done in the laboratory since it requires. Experimental investigations on the dissolved gas analysis method.

Fault severity is the core property in transformer maintenance. Sampling of transformer oil by syringe as per iec 60475. Icmcompact dissipation factor and partial discharge measurement on cable. The condition monitoring tests includes ir, tandelta, magbalance, winding resistance, turns ratio, bushing tandelta, dga, oil bdv, etc.

Solomon corporation dga testing of transformers part 2. Main purpose of the the oil in a tank is to be an insulator. Type 3 transformers in this category show signs of serious fault gas concentrations or. Tops is a set of specifications developed and maintained by the doble oil committee and is the basis for the annual oil survey testing.

Jun 19, 2017 the dga test measures dissolved gases in the transformer oil and is capable of detecting. It is believed that there is room for improvement in combining svm. Diagnostic tool for transformer fault detection based on. Our 50 years of experience in transformer oil analysis guarantees precise and accurate analytical results. Dec 06, 2012 dissolved gas analysis dga of power transformer oil shivaji choudhury 2.

White paper applying dissolved gas analysis to distribution. By combining various dga techniques and interpreting classical dga with fuzzy logic system approach, we have increased the predictability of. This product information is divided into the following sections. The kelman transport x is a compact portable dissolved gas analysis dga system which can be used to analyze oil samples for all dissolved fault gases and moisture. These gases can be detected in transformer insulating oil using sensitive and. Dga results of oil samples drawn from transformers of different. If a transformer is overloaded for a long period of time, the deteriorating condition of the cellulose will shorten the life of. This reaction is accelerated by exposure to light, therefore sampling devices made of transparent materials i. Advantages of the togatransformer oil gas analyzerinvolving. School of engineering, department of electrical engineering, blekinge institute of technology, s371 79 karlskrona phone. Product information dissolved gas analysis and supervision of. While in service transformer undergoes various termal,chemical,electrical stresses due to that some gases generated these gases known as fault gases which r quantitified in extremely low level in parts per million ppm, the test which is conducted to analyse these fault gases known as dga test. In 30 bayesian methodic has been used to combine expert judgment and avail.

Different dga techniques for monitoring of transformers. Transformer oil introduction transformer oil is like a blood in human body. Condition monitoring of power transformers using dissolved. In general, the solubilities and thermal decomposition products of beta fluid are very similar to those from conventional transformer oil. Thus, a more intuitive approach is combining the results derived from all major test. Analysis of the gases dissolved in power transformer oil is recognized as the most useful tool for early detection and. With dga, samples are taken of the oil s exhaust gases to determine if any events have occurred that might be detrimental to the transformer and reduce its life. The use of dissolved gas analysis dga as a method for determining the. Analysis of a transformer oil sample for dissolved gases by a laboratory is an established technique recognised as the most important test for monitoring power transformers.

Transformer oil gas analysis cont manual sample handing. Variations of type 1 transformers may exist pending past records and age of units. The acidity of insulating oil is generally measured by the required quantity in milligram of koh to entirely neutralize the acidity of a specific quantity in gram of the oil. The dga will require the removal of an oil sample from the transformer and this can be done without deenergization of the transformer. Monitor and maintain transformer oil during its service life. To optimize cost and performance, hybrid insulation materials combining. A dga test can identify an overloaded transformer by a test result showing high carbon monoxide, high carbon dioxide, and in extreme cases, even elevated methane and ethylene. This provides you with a reliable status diagnosis of your transformer at any time during operation. Gray transformer chemistry services introduction the fault free operation of power transformers is a factor of major economic importance and safety in power supply utilities and industrial consumers of electricity. The dga requires routine oil sampling and modern technologies for online gas monitoring. The installation and testing of the transformer verifies its. Ge grid solutions kelman dga 900 installation manual. Dga has become a standard in the electrical maintenance industry throughout the world and is considered to be the most important oil test for transformer oils in electrical apparatus. Gc2010d measures dissolved gases in transformer oil.

The above standard testing is offered in specific diagnostic suites designed to provide the maximum condition information on the transformers. Designed for both the new user and experienced equipment operator, ppmreport is available in six different languages. Newly installed transformers should be sampled frequently within the first 12 months i. Transformer failures are often due to the lack of the dielectric strength of oil insulation and will. Whenever a transformer undergoes abnormal thermal and electrical stresses, certain gases are produced due to the decomposition of the transformer oil. The fault types cases that are provided have been chosen by combining. Dissolved gasin oil analysis the most important test that can be done on the liquid insulation of a transformer is an annual dissolved gas analysis dga. In this method a sample of the oil is taken from the unit and the dissolved gases are extracted.

Valve option 752 automate two valves 78900047 configured per. Dissolved gas analysis iec 60599 for many years the method of analysing gases dissolved in the. Dissolved gas analysis dga of transformer oil is one of the key methods of assessing transformer health 1. Pdf oilimmersed power transformers condition diagnosis. Optimus dga monitor opt100 for power transformers online. Therefore, you dont want to have a water in your transformer because water is a very good conductor and could cause a partial discharge. Astm d3612 test methods for analysis of gases dissolved in electrical insulating oil by gas. Requires 1 litre of oil in a polyethylene container provided by src. Background dissolved gas analysis dga is the most important tool in determining the condition of a transformer. These two key points are essential when interpreting the dga results for distribution transformers. Dissolved gas analysis iec 60599 for many years the method of analysing gases dissolved in the oil has been used as a tool in transformer diagnostics in order to detect incipient faults, to supervise suspect trans.

The doble materials laboratory performed experiments in which a voltage of 25 kv was applied to sustain an arc through cross oil crosstrans 106 transformer oil in a test cell equipped with a needle to. Dissolved gas analysis dga technique is commonly used to identify. H 2 ch 4 c 2h 2 c 2h 4 c 2h 6 co tdcg avrg caution ppm. Yes the results show over heating of oil with out any arcing or involvement of cellulose. If a proactive approach is adopted based on the condition of the transformer oil, the life of the transformer can be extended. Oilimmersed power transformers condition diagnosis with. This reliabilitybased dga quick start guide is documentation to help toa4 users understand and use new software features relating to reliabilitybased dissolvedgas analysis r dga for oil filled power transformers.

The dga test analyzes the gas concentrations that are dissolved in the transformer oil. Power transformer diagnostics, monitoring and design. Much in the same way that a doctor can analyze a patients blood to determine certain health problems, the trained transformer owner can detect problems within the. Dga testing of transformers part 2 february 27, 2014 in part 1 of this twopart series on dissolved gas analysis dga and testing of oilfilled transformers, it was stated that dga evaluation of combustible gasses is used to determine possible causes of a transformers internal problem or fault.

Dga after application of 100 breakdown tests in the oil samples. H2, o2, n2, co, co2, ch4, c2h6, c2h4 and c2h2 are analyzed. Morgan schaffer pioneered dissolved gas analysis dga in america. Mte offers a broad range of products and solutions for the online gasin oil monitoring of transformers online dga. The hillside aluminium smelter is located in richards bay, 200 kilometers north of durban, kwazulunatal province, south africa. Dukarm deltax research inc 20060320 transformer dissolvedgas analysis dga is the measurement of gases dissolved in the insulating fluid of a transformer, and the interpretation of the measurement data so obtained, in combination with other information about the transformer and its environment. Optimising the future management of large transformers on networks to maximise the utilisation and full potential life of existing transformers and to ensure. Pdf residual life assessment with dga, furan content in. What should be the water content in transformer oil, and. After the first year, an annual dga test should suffice.

This paper uses dissolved gas analysis to study the history of different transformers in service, from which dissolved combustible gases dcg in oil are used as a diagnostic tool for evaluating the condition of the transformer. Dga values of transformer oil prc electrical 12 jan 09 01. Once power transformer is charged and commissioned, transformer oil becomes a key element to monitor the healthiness of unit and dga is one of the important tools to predict probable fault developing in unit as well as analyse insipient trippings. In case of a manual operating mode, the oil samples are first injected into a vacuum. Dga tests results from 38 power transformers in a developing country and will propose a maintenance decision making procedure using the iec 605992007 and duvals triangle. Oil diagnostic suites for transformer oil diagnostics. Optimus dga monitor opt100 for power transformers online monitoring. Much attention is needed on maintenance of transformers in order to have fault free electric supply and to maximize the lifetime and efficacy. The most sensitive and reliable technique for evaluating the health of transformer is dissolved gas analysis dga.

134 605 391 25 1644 61 1179 1600 1186 37 271 1029 70 414 223 71 725 665 30 1279 161 1214 1547 141 957 1320 24 151 1245 1236 1255 656 320 1173 355 534 1446 253 233 536 1339